China 1000kg Boiler Supplier and Factory Manufacturers


China 1000kg Boiler Supplier and Factory Manufacturers

China 1000kg Boiler Supplier and Factory Manufacturers
  • Offshore price : $8,999.00 - $100,000.00
  • Minimum order quantity : 1 set
  • Supply Capacity : 10 units/month
  • Manufacturer/Brand : TOBO BOILER
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

  • SMA1 Boilers 2010fin - BOMI

    21. The lowest temperature at which condensation can be prevented in the flue gas passages of a hot water heating boiler is: a. 170ºF. b. 190ºF. c. 210ºF. d. 130ºF. 22. The device that ensures that steam pressure will not force the boiler water back into the return line is a: a. condensate trap. b. direct feed pump. c. Hartford loop.Get Price

  • The Definitive Guide to Condensing Water Heaters or Boilers

    By contrast, a condensing boiler using the same basis is around 95% efficient at full load. Using Net calorific values, these figures both increase by about 10%, so that the condensing boiler has an apparent efficiency of 103% – because it is extracting more heat from the flue gas that the net calorific value recognises.Get Price

  • Question about derating a gas fired, atmospheric steam

    Dec 18, 2021 · 1. to much water to heat to produce steam at a quantity that is needed. 2. Insufficient heat in the flue gases to reach a proper stack temperature. 3. Soot depositing on the fire sides of the boiler. 300% is grossly over sized, in my experience 25% derate is about all you can do safely. As to removing sections>. 1.Get Price

  • Flue Temperature - an overview | ScienceDirect Topics

    The condensing boiler concept is not applicable to oil or coal, which normally have a more acidic condensate. Fuel savings of from 14% to 18% can be achieved. Spray recuperator The principle of the spray recuperator is similar to that of the condensing boiler, and again is restricted to gas firing. In this case the condensation takes place by Get Price

  • If I pipe the condensate discharge from my combi-boiler

    The condensate expelled from a condensing boiler is acidic, with a (pH between 3 and 4) about the same as an orange. Condensing boilers require a drainpipe for the condensate produced during operation. This consists of a short length of inexpensive polymer pipe with a vapour trap to prevent exhaust gases from being expelled into the building.Get Price

  • condensing economizer flue gas - Popular condensing

    Oil Lpg Gas Fired Condensing Steam Boiler For Food Machinery Plant General Introduction Condensing steam boiler takes the advantage of high efficiency condenser and economizer,to absorb the sensible heat in the high temperature flue gas that..Get Price

  • Boiler Flue Changes Required When Replacing A Gas Boiler

    Horizontal Flue For Gas Boiler. A typical gas boiler flue (or pipe to most people) has a diameter of 100mm, with two different channels for gases to flow. The 60mm central pipe is used to take the exhaust gases outside, whilst the 100mm outer ring is used to bring in fresh air. Boiler Flue Terminal. The end of the flue is called the terminal Get Price

  • Boiler condensate pipe regulations| Living by HomeServe

    Sep 22, 2021 · A condensing boiler is any boiler that uses condensing technology to reuse the heat they generate from burning fuels such as gas or oil. Before 2005, older, non-condensing boilers wasted between 30-50% of heat due to combustion gases escaping via the flue. A condensing boiler, in comparison, can be up to 92% efficient.Get Price

  • What is a High Efficiency Gas Boiler? | U.S. Boiler Company

    Aug 21, 2019 · With a standard, conventional boiler, some of the energy that is used to heat the boiler, whether it is a fossil fuel or natural gas, gets lost in the combustion process. When fuel is burned in a boiler, it produces flue gas, similar to the exhaust from your car. This gas leaves the combustion chamber and enters the flue passages.Get Price

  • Can you enclose a gas boiler? - TreeHozz.com

    Although the boiler cupboard does not require any form of air vents or additional ventilation, the boiler requires oxygen in order to burn the gas correctly. The flue is the pipe that allows the waste gases produced by your boiler to be released from your home.Get Price

  • Condensation Of Flue Gases In Boilers

    condensation boilers - condensation boilers. fired boilers have the effect of trapping of harmful substances in the condensation of water vapor from the flue gases even higher. 2 Application problem The combustion of a hydrocarbon fuel, depending on the type of fuel in the flue gas is formed about 10-15 %Get Price

  • Boiler Flue Regulations Explained | Boiler Guide

    Location. Under the boiler flue position regulations, the flue has to be positioned a certain distance from any parts of the home that can be opened up such as windows and doors. How far this is will depend on the size of your boiler but is typically between 30-60cm above, below or to the side of an opening.Get Price

  • 5 Factors Killing Your Industrial Boiler Efficiency & What

    Flue gas condensation is a good thing when going for record efficiencies in a hydronic system, but the boiler and stack must be designed to handle the condensate. If either are incorrectly selected for the application or are not installed properly, flue …Get Price

  • Can a boiler flue go through a chimney?

    The two main gases your gas condensing boiler produces are water vapour and carbon dioxide. Nitrogen oxide can also be created when the oxygen and nitrogen in the air are burned together. If your boiler isn't burning the gas correctly, carbon monoxide could be produced too.Get Price

  • What Is A Condensing Boiler? | Boiler Advice | Vaillant UK

    A condensing boiler uses condensing technology to make better use of the heat it generates. When a fuel such as gas or oil is burned, gasses are released via a flue. In a non-condensing boiler system these gasses would be released into the atmosphere and their heating potential would be lost. However, in a condensing boiler the hot gasses are Get Price

  • What happens if a boiler flue is blocked? | Viessmann

    If your boiler's flue becomes blocked, these gases have nowhere to go other than back inside your home. In some cases, this can be fatal, with the NHS stating that around 60 deaths a year are caused by carbon monoxide poisoning. The two main gases your gas condensing boiler produces are water vapour and carbon dioxide.Get Price

  • MAXIMUM ENERGY GAIN FROM FLUE GASES

    Our flue gas ercs condensation plants recover up to 50 % of the boiler output from thermal energy in heat contained in otherwise unused flue gas. The latent heat of the evaporation or condensation heat is recovered by condensing flue gas. In addition, one part of the sensible heat can be extracted by means of a decrease in tem-Get Price

  • condensing economizer flue gas - Popular condensing

    Oil Lpg Gas Fired Condensing Steam Boiler For Food Machinery Plant General Introduction Condensing steam boiler takes the advantage of high efficiency condenser and economizer,to absorb the sensible heat in the high temperature flue gas that..Get Price

  • Rotted boiler sections — Heating Help: The Wall

    Running a good ground to the piping can eliminate this. I have seen cast iron boilers rot from the outside in from flue gases condensing from venting issues and even less than 4 years. Flue gas condensate is just as acidic as steam condensate and might explain why the corrosion is …Get Price

  • Flue gas condensation | Hearth.com Forums Home

    Oct 20, 2009 · Flue condensation usually happens as a result of a boiler that's VERY efficient at extracting heat from the flue gas, possibly combined with a poorly insulated flue. It can cause deterioration of the flue (ceramic or metal) over time. You need flue gas below about 150 degrees F to have this problem - not likely for most of us.Get Price

  • Boiler condensate pipe connection | DIYnot Forums

    Feb 22, 2020 · That should be the other way around, the small white pipe going through the wall (21.5mm solvent weld) should be connected to the condensate pipe coming out the boiler and then the black pipe should run through the wall to connect to the stack. You can then introduce an inline one way valve/trap into the 21.5mm pipe.Get Price

  • BetterBricks | Boiler Operations & Boiler Maintenance | O&M

    Return water temperatures above 130oF prevent condensation of the flue gas and result in the boiler operating no more efficiently than a traditional boiler. Figure 8: Effect of Return Water Temperature on Efficiency of Condensing Boilers. Flue Gas Economizers. Flue gas economizers offer the best opportunity for heat recovery (3).Get Price

  • flue gas condensation question — Heating Help: The Wall

    if you are going to get a condensing boiler and run it into the same chimney, you need stainless coax piping - so decide first, if your chiminey is exposesd on three sides and might be leaking flue gases - why bother - just get a few co detectors for you home and have'a'nice'day - if it aint broke unless you can do this yourself cheaply, spend your money on boiler piping first - you need to …Get Price

  • Question about derating a gas fired, atmospheric steam

    Dec 18, 2021 · 1. to much water to heat to produce steam at a quantity that is needed. 2. Insufficient heat in the flue gases to reach a proper stack temperature. 3. Soot depositing on the fire sides of the boiler. 300% is grossly over sized, in my experience 25% derate is about all you can do safely. As to removing sections>. 1.Get Price

  • Boiler Flues - Ultimate Guide with Boiler Flue Regulations

    Nov 05, 2019 · Boiler flues are fitted when using combi, regular, and system boilers. The only exception that may apply to a small number of homeowners is a back boiler. This is a type of boiler that is fitted behind a fireplace. If you have a gas boiler behind your fire, the emissions will exit through your chimney, rather than via a boiler flue.Get Price

  • What is a condensing boiler? Why they don't condense

    Mar 05, 2020 · A condensing boiler is a form of gas boiler that can work at a higher efficiency. Non-condensing gas boilers could lose up to 40% of the heat they generated via the flue, whereas condensing boilers can recover most of that heat by capturing it before it leaves the flue and re-cycling it to pre-heat the boiler.Get Price

  • The Powermax Boiler: The Silent Killer - Smart Plumbing

    The gas valve settings on this boiler are known to drift over time. These need checking and recalibrating (if required) on every annual service. If the settings are not correct, carbon monoxide can be produced in vast quantities. Flue gas readings can only be taken from the flue on this boiler where it exits the building.Get Price

  • condensing economizer flue gas - Popular condensing

    Oil Lpg Gas Fired Condensing Steam Boiler For Food Machinery Plant General Introduction Condensing steam boiler takes the advantage of high efficiency condenser and economizer,to absorb the sensible heat in the high temperature flue gas that..Get Price

  • Flue Gas Condensation Could Be Killing Your Boiler

    Is the plume from a condensing boiler dangerous?Get Price

  • Boiler Economizer: Boost Your Boiler's Performance I RasMech

    Mar 03, 2021 · That is where boiler economizers come in to reduce that heat loss. Remember, we need a fluid that can use the heat AND is at a lower temperature than the flue gas. Dry Economizer. Feedwater leaving a deaerator at 225 may be 100 F cooler than the boiling temperature in the boiler, so feedwater can absorb the heat.Get Price

  • Consider Installing a Condensing Economizer

    by transferring heat from the flue gas to the boiler feedwater. For natural gas-fired boilers, the lowest temperature to which flue gas can be cooled is about 250°F to prevent condensation and possible stack or stack liner corrosion. The condensing economizer improves waste heat recovery by cooling the flue gas below its dew point, which is Get Price

  • Managing Condensate for Condensing Boilers - Automatic Heating

    The condensing process is achieved by passing the piped hot flue gases through the cooler return water flowing back into the boiler. Flue gas starts to condense when it drops below its dew point of 55°C. This is why condensing boilers are designed to accommodate a return water temperature of 54°C or less.Get Price

  • How to turn down the flow temperature on your boiler

    Oct 18, 2021 · The Heating Hub. Turning down the 'flow' temperature of your heating water can save around 6-8% on fuel bills, Jo explains why and how to do it. A recent report by the Heating and Hot Water Council (HHIC)* found that households can save around 6-8% on their gas bill just by turning down the flow temperature on their condensing combi boiler.Get Price

  • Condensing Boiler Fumes - South Gloucestershire

    heat exchanger within the boiler and used to preheat the return water. As a result the temperature of the gases leaving the flue of a condensing boiler is typically 50-60°C compared with 120-180°C in a current non-condensing boiler. At the same time an amount of water or 'condensate' is produced. A condensing boiler will always have aGet Price

  • Series WBV - PB Heat: Peerless® Boilers

    6. Chimney flue gas condensation is affected by a number of factors such as chimney design, flue connector length, sulfur content in fuel oil, and flue gas temperature. If your application experiences flue gas condensation, installation of a listed corrosion resistant metal liner is required. • External chimneys are more susceptible to flueGet Price

  • You Have Choices for Your Boiler Flue Materials | UEP Sales

    Feb 24, 2021 · You Have Choices for Your Boiler Flue Materials. February 24, 2021. United Energy Products prides itself in being your local go-to expert when it comes to venting your fuel burning appliances. We've invested time and talent over the years convincing you to avoid PVC for venting your high-efficient, condensing boilers, particularly for boilers Get Price

  • Flue Gas Condensers | CleanBoiler.org

    Protecting Boilers Against Flue Gas Condensation | 2017-08 Get Price

  • Resources | Boiler Specialists

    Flue gas condensation can occur in any hot water boiler. The causes of this condensation and the importance of properly mitigating it are easily misunderstood. Flue gas condensation is also part of the reason why condensing boilers can have efficiencies up to 99% whereas a typical non-condensing boiler will max out around 80–85% efficiency.Get Price

  • Condensation Of Flue Gases In Boilers

    condensation boilers - condensation boilers. fired boilers have the effect of trapping of harmful substances in the condensation of water vapor from the flue gases even higher. 2 Application problem The combustion of a hydrocarbon fuel, depending on the type of fuel in the flue gas is formed about 10-15 %Get Price

  • Rainwater coming through flue into boiler? Anyone seen it

    Sep 03, 2019 · The boiler's been out of action for a few days so there hasn't been any heat to drive off this moisture. There was torrential rain here overnight, and so I'm wondering whether this is rainwater coming in. The boiler has the standard horizontal flue option, i.e. one 90 degree bend then about 300mm of flue going straight through the wall to Get Price

  • Question 1, Boiler Flue dripping. — MoneySavingExpert Forum

    Feb 14, 2013 · The flue should rise from the boiler at a 3 degrees angle so that the condensation can run back into the boiler and out through the drain. If it is dripping then it is likely that the flue is sitting straight through the wall. Over time a nice …Get Price

  • Are fumes from a boiler flue dangerous?

    4.1/5 (43 Views . 13 Votes) Boiler flues are a crucial part of your heating system. They are a way for combustion fumes that have been created by your boiler to be released outside the home. If your boiler isn't burning the gas correctly, carbon monoxide could be produced too. Boilers are made to be safe, and these gases shouldn't harm you.Get Price

  • Protecting Boilers Against Flue Gas Condensation | 2017 …

    Protecting Boilers Against Flue Gas Condensation | 2017-08 Get Price

  • Is the plume from a condensing boiler dangerous?

    Jan 28, 2020 · The two main gases your gas condensing boiler produces are water vapour and carbon dioxide. Do condensing boilers give off carbon monoxide? Boilers can produce carbon monoxide naturally, but the gas is usually carried out of your house via a flue. If your flue is blocked, the carbon monoxide has nowhere to go and will escape into your home Get Price

  • Flue Gas Heat Recovery Systems - TheGreenAge

    Flue gas heat recovery systems requires very little maintenance, with no need for mains electricity. They can they be used in combination with a number of renewable technologies and help cut water use by your boiler by up to 6%, which is helpful if you are on a water meter.Get Price

  • Are boiler fumes dangerous? - AskingLot.com

    Apr 21, 2020 · the gases you see are extremely unlikely to be carbon monoxide, new boilers run very clean and give of allot less harmful gases than older types. what you can see is plumage (water vapour or condensation, hence condensing boiler) and is pretty harmless. its just a visible nuisance but looks worse than it is.Get Price

  • Condensation Of Flue Gases In Boilers

    condensation boilers - condensation boilers. fired boilers have the effect of trapping of harmful substances in the condensation of water vapor from the flue gases even higher. 2 Application problem The combustion of a hydrocarbon fuel, depending on the type of fuel in the flue gas is formed about 10-15 %Get Price

  • Is a high efficiency, condensing gas boiler the best

    Aug 13, 2018 · A high efficiency, gas-fired condensing boiler is one of the most economical and clean ways to heat your home, reduce your monthly heating bills, and lessen environmental impact. In most circumstances, a condensing boiler can be used to replace an existing boiler in an older heating system.Get Price

  • Prepare your Boiler for Winter - The Severn Group

    Oct 02, 2015 · There may be an underlying issue that we need to look at. Flue gas temperature, gas pressure, and oil pressure and temperature should all be checked on a daily basis as well. Let your boiler breathe. Boilers need adequate ventilation. If they're inside a closet, don't store clothing or shoes in the same space. Airflow is important!Get Price